The Paton Welding Journal, 2005, #5, 48-49 pages
Calibration of triangular optical sensors
F.N. Kiselevsky, V.A. Kolyada
E.O. Paton Electric Welding Institute of the NASU.
11 Kazymyr Malevych Str., 03150, Kyiv, Ukraine.
Abstract
Procedure of calibration of triangular optical sensors used in automation of welding processes has been offered. It allows calibration of sensors after their assembly into welding equipment under the industrial conditions.
Keywords: arc welding, welding units, triangular optical sensor, standard article, laser generator of line, radiation plane, mathematical model, transformation of coordinate sys-tems, perspective transformation
References
1. Powell, B.W., Kennedy, L.Z., Burroughsa, I.A. Weld-bead profilometer. Pat. 5264678 USA. Publ. 23.11.93.
2. Zhang, Z. (2000) A flexible new technique for camera calibration. IEEE Transact. on Pattern Analysis and Machine Intelligence, 22(11), 1330–1335.
3. Novikov, S.O., Lebedev, O.A., Zakharenko, G.V. (2003) Measurement and examination of 3D objects in conditions of incomplete information. Inform. Tekhn. i Vych. Sistemy, 2, 61–63.
4. Ammeral, L. (1992) Principles of programming in computer graphics. Moscow: Sol Sistem.
Suggested Citation
F.N. Kiselevsky,
V.A. Kolyada (2005) Calibration of triangular optical sensors.
The Paton Welding J., 05, 48-49.