Print
2000 №09 (03) 2000 №09 (05)


The Paton Welding Journal, 2000, #9, 19-25 pages

Elimination of cracks in steel structures using design-technological measures

H. Herold, N. Woywode

Magdeburg University, Germany

Abstract
Numerous open and closed cracks were detected in thick-walled welded elements of span structures of a metallurgical workshop made from increased-strength steel plates 11-45 mm thick. Cracks were registered also in welds between shafts and drum bases of a belt conveyer. Explanations of formation of this type of defects are given. Design-technological measures are suggested for elimination of such cracks.
Keywords: welded structures, increased-strength steels, hot galvanizing. quenching structures, thermal stresses, preheating, groove preparation

References

1. Schmidt, J. (1996) Das chemische Element Zink. Bedeutung als Korrosionsschutzstoff. Der Praktiker, 11, 508 - 513.
2. Herold, H. (1997) Schadensfall-Hallenkonstruktion Institut fur Fuge - und Strahlteclrnik der Otto-von-Guericke-Universitdt. Magdeburg.
3. Radeker, W. (1953) Die Erzeugung von Spannungsrissen in Stahl durch flussiges Zink. Stahl und Eisen, 10, 654 – 658.

Suggested Citation

H. Herold, N. Woywode (2000) Elimination of cracks in steel structures using design-technological measures. The Paton Welding J., 09, 19-25.