Print

2012 №07 (09) 2012 №07 (01)

The Paton Welding Journal 2012 #07
The Paton Welding Journal, 2012, #7, 38-41 pages  

INFLUENCE OF VIOLATIONS OF WELDING GUN AXIAL SYMMETRY ON FOCAL SPOT POSITION

O.K. NAZARENKO and V.A. MATVEJCHUK


E.O. Paton Electric Welding Institute, NASU, Kiev, Ukraine
 
 
Abstract
In addition to the known requirements to stability of heating spot position on an item specified in international standard ISO 14744-6, violations of adjustment of electron beam welding gun and procedure of their elimination are considered.
 
 
Keywords: electron beam welding, EB gun, triode emission system, electromagnetic focusing system, violations of axial symmetry, beam crossover, focal spot, instability of dimensions and position, welding gun adjustment
 
 
Received:                27.04.12
Published:               28.07.12
 
 
References
1. (2000) ISO 14744-6: Welding Е acceptance inspection of electron beam welding machines. Pt 6: Measurement of stability of spot position.
2. Glazer, V. (1957) Fundamentals of electron optics. Moscow: Gostekhteorizdat.
3. Kelman, V.M., Yavor, C.Ya. (1950) Electron optics. Moscow; Leningrad: AN SSSR.

Suggested Citation

O.K. NAZARENKO and V.A. MATVEJCHUK (2012) INFLUENCE OF VIOLATIONS OF WELDING GUN AXIAL SYMMETRY ON FOCAL SPOT POSITION. The Paton Welding J., 07, 38-41.