The Paton Welding Journal, 2005, #10, 27-32 pages
Typical damages of welded metal structures of bridges
V.A. Kovtunenko, A.G. Sineok, A.M. Gerasimenko, V.A. Zadorozhny
E.O. Paton Electric Welding Institute of the NASU
11 Kazymyr Malevych Str., 03150, Kyiv, Ukraine.
Abstract
Analysis results are presented on characteristic damages of weldments and welded joints in metal structures of active bridge spans in Kiev. Main factors affecting formation and propagation of the above damages are given. The top priority measures aimed at improvement of operational safety of bridges are recommended
Keywords: welded metal structures, weldments and welded joints, bridge framework, metal structures life, corrosive damage, stress-strained state
References
1. SNiP 3.06.07-86: Bridges and pipes. Rules of inspections and tests. Gosstroj SSSR. Introd. 01.07.87.
2. VSN 4-81: Instruction on conducting of inspection of bridges and pipes on highways. Minavtodor RSFSR. Introd. 01.01.82.
3. (1989) Guidelines on inspection and reinforcement of operated welded span structures. MPS of Russia, NUM, LIIZhT. Introd. 01.01.90.
4. (1989) Manual on design of steel structure reinforcement (to SNiP 11-23-81). Ukrniiproektstalkonstruktsiya. Moscow: Strojizdat.
5. DBNV 3-6-2002: Structures of transportation. Bridges and pipes. Inspections and tests. Derzhhud of Ukraine. Introd. 01.10.2002.
6. DBN’ 362-92: Evaluation of technical state of steel structures, maintained production premises and buildings. Ukrarkhstrojinform. Introd. 01.07.92.
Suggested Citation
V.A. Kovtunenko,
A.G. Sineok,
A.M. Gerasimenko,
V.A. Zadorozhny (2005) Typical damages of welded metal structures of bridges.
The Paton Welding J., 10, 27-32.