The Paton Welding Journal, 2005, #12, 5-9 pages
Computer programs for designing effectiveness of pipeline protection by the method of non-linear polarization
S.G. Polyakov, A.A. Rybakov, L.I. Nyrkova
E.O. Paton Electric Welding Institute of the NASU
11 Kazymyr Malevych Str., 03150, Kyiv, Ukraine.
Abstract
A computer program has been developed for calculation of electrochemical parameters and its performance has been verified in the laboratory and in the route, when testing a gas pipeline, using an electrochemical microprocessor system (ECMS). Obtained data on the rate of soil corrosion of pipeline metal correlate in a satisfactory manner with that of mass measurements. Possibility of evaluation of the rate of residual corrosion of pipeline metal in a coating defect using ECMS and developed program, allows an objective assessment of the degree of pipeline protection and taking a wellgrounded decision on the sequence of repair of pipeline section with damaged insulation.
Keywords: pipelines, insulation coating, corrosion rate, potential, protection effectiveness, potentiometry, mass measure¬ment, computer calculations
References
1. Rossini, G. (1994) An improved to the Mansfields method for computing electrochemical parameters from polarization data. Corros. Sci., 36(4), 567–578.
2. Rejngeverts, M.D., Khajt, Yu.G. (1992) On calculation of corrosion rate of metals from the data of polarization measurements. Zashchita Metallov, 28(5), 852–855.
3. Rejngeverts, M.D., Semyonova, N.G., Sergeeva, N.A. et al. (1992) Determination of kinetic parameters of general corrosion from the data of polarization measurements. In: Abstr. of Conf, on Protection-92 (Moscow, Sept. 6–11, 1992). Moscow.
4. Rossini, G. (1994) The determination of Tafel slopes by an integral method. Corros. Sci., 36(1), 113–125.
5. Yeum, K.S., Devereux, O.F. (1989) An iterative method for fitting complex electrode polarization curves. Corrosion, 45(6), 478–487.
6. Jensen, M., Britz, D. (1990) A linearized least-squares method of corrosion parameters calculation. Ibid., 46(2), 111–114.
7. Qaumar, J., Husain, S.W. (1992) Application of a new computational method to determine corrosion current in a cathodically protected system. Brit. Corros. J., 27(2), 125–127.
8. Qaumar, I., Husain, S.W. (1990) New computational method to determine corrosion Tafel slopes and corrosion rates from electrode kinetic measurements. Ibid., 25(30), 202–204.
9. Rossini, G. (1990) The generalization of the three point method and its application to the corrosion rate measurement. Ibid., 30(1), 9–21.
10. Rossini, G. (1996) The use of the three point method for evaluating corrosion rates. Ibid., 38(7), 1019–1031.
11. Rubashov, A.A., Kuzmak, A.E. (1989) Determination of corrosion current density and tracer Tafel constants of polarization curves. In: Corrosion protection in chemical industry. Moscow.
12. Rossini, G. (1999) The evaluation of corrosion rates with the generalized inflection point method. Corros. Sci., 41(11), 2129–2142.
13. Polyakov, S.G., Paton, B.E., Rybakov, A.O. et al. Method of determination of corrosion state of underground metallic installations. Pat. 242121 Ukraine. Int. Cl. G 01 N 17/00, G 01 N 17/04. Publ. 07.07.98.
14. Polyakov, S.G., Rybakov, A.A., Nyrkova, L.I. (2001) Electrochemical methods of corrosion state control of pipelines. Fiziko-Khim. Mekhanika Materialov, 2, 16–21.
15. Polyakov, S.G., Rybakov, A.A., Nyrkova, L.I. (2001) Scientific principles and technical means of electrochemical monitoring of corrosion state of main pipelines. In: Sci.-Techn. Meeting of National Joint Stock Company «Neftegaz Ukrainy», Affiliated Company «Ukrtransgaz», Open Joint Stock Company «Gazprom» on Problems of Increase of Reliability and Efficiency of Gas-Transport System. Kiev: Ukrtransgaz.
Suggested Citation
S.G. Polyakov,
A.A. Rybakov,
L.I. Nyrkova (2005) Computer programs for designing effectiveness of pipeline protection by the method of non-linear polarization.