The Paton Welding Journal, 2003, #12, 18-21 pages
Effect of power circuit parameters on fluctuations of current in turbulence-type plasmatrons (calculation experiment)
V.L. Dzyuba, G.S. Kalyuzhny
V. Dal East-Ukrainian National University, Lugansk, Ukraine
Abstract
Dependence of values of large-scale current fluctuations in turbulence-type plasmatrons upon the power circuit parameters has been studies by the method of a calculation experiment. As shown by its results, the value of the arc current fluctuations first decreases with increase in the natural frequency of the power circuit, and then remains approximately at a constant level that lowers with increase in circuit inductance.
Keywords: plasmatron, arc current stabilisation, largescale fluctuations, arc shunting, calculation experiment
References
1. Zhukov, M.F., Koroteev, A.S., Uryukov, B.A. (1975) Applied dynamics of thermal plasma. Novosibirsk: Nauka.
2. Dautov, G.Yu., Dzyuba, V.L., Karp, I.N. (1984) Plasmatrons with stabilised electric arcs. Kyiv: Naukova Dumka.
3. Zhukov, M.F., Devyatov, B.N., Novikov, O.Ya. et al. (1987) Theory of thermal electric arc plasma. Part 2. Nonstationary processes and radiation exchange in thermal plasma. Novosibirsk: Nauka.
4. (1973) Stability of electric arc burning. Novosibirsk: ITF AN SSSR.
Suggested Citation
V.L. Dzyuba,
G.S. Kalyuzhny (2003) Effect of power circuit parameters on fluctuations of current in turbulence-type plasmatrons (calculation experiment).
The Paton Welding J., 12, 18-21.