Optimisation of parameters of additional gas shielding in submerged arc welding and surfacing of copper and its alloys

V.N. Koleda, V.M. Ilyushenko


E.O. Paton Electric Welding Institute, NASU, Kiev, Ukraine
 
 
Abstract
The paper presents the results of evaluation of influence of a combined shielding on gas saturation of metal at the stage of a drop and a pool in welding and surfacing of copper and its alloys. Parameters of the process of submerged arc welding and surfacing using an additional gas shielding were optimized. A new method of a pulsed supply of shielding gas into the arc zone in submerged arc welding and surfacing was developed.
 
 
Keywords: arc welding, submerged arc surfacing, copper and copper alloys, gas shielding, hydrogen, porosity prevention
 
 
Received:                ??.??.??
Published:               28.11.10
 
 
References
1. Gurevich, S.M. (1990) Reference book on welding of nonferrous metals. Kiev: Naukova Dumka.
2. Paton, B.E. (1974) Technology of fusion electric welding of metals and alloys. Moscow: Mashinostroenie.
3. (2006) Machine building: Encyclopedia. Vol. 4: Welding of nonferrous metals and alloys. Ed. by B.E. Paton. Moscow: Mashinostroenie.
4. Monnean, P. (2000) Les liaisons du cuivre. Vide Sci., Techn. et Appl., 55(296), 147-158.
5. Podgaetsky, V.V., Mandelberg, S.M., Bender, V.S. et al. (1973) Submerged-arc welding using gas-saturated flux. Avtomatich. Svarka, 6, 28-31.
6. Ilyushenko, V.M., Bosak, L.K. (1984) Influence of oxidation level of flux on porosity in welding of copper. Ibid., 4, 67-68.