The Paton Welding Journal, 2015, #5-6, 90-92 pages
New electrodes for repair surfacing of damaged lining of impeller chamber of hes hydropower units
K.A. Yushchenko, Yu.N. Kakhovsky, A.V. Bulat, V.I. Samojlenko And N.Yu. Kakhovsky
E.O. Paton Electric Welding Institute, NASU. 11 Bozhenko Str., 03680, Kiev, Ukraine. E-mail: office@paton.kiev.ua
Abstract
New electrodes of ANV-70BG grade were developed. Relationship of structural and chemical inhomogeneity in transition zone between low-carbon steel and highly-alloyed deposited metal depending on type of the latter and value of welding current was investigated. 4 Ref., 4 Tables, 3 Figures.
Keywords: coated-electrode manual arc surfacing, low-carbon steel, highly-alloyed deposited metal, transition zone, structural and chemical inhomogeneity, cracks, corrosion
Received: 25.03.15
Published: 28.07.15
References
1. Gotalsky, Yu.N. (1981) Welding of dissimilar steels. Kiev: Tekhnika.
2. Zemzin, V.N. (1966) Welded joints of dissimilar steels. Moscow: Mashinostroenie.
3. Frolov, K.V., Paton, B.E., Belyanin, P.N. (2006) Machine-building: Encyclopedia, Vol. 3, 4. Moscow: Mashinostroenie.
4. Pavlov, I.V., Antonets, D.P., Gotalsky, Yu.N. (1980) To problem of mechanism of transition layer formation in fusion zone of dissimilar steels. Avtomatich. Svarka, 7, 5-7.
Suggested Citation
K.A. Yushchenko, Yu.N. Kakhovsky, A.V. Bulat, V.I. Samojlenko And N.Yu. Kakhovsky (2015) New electrodes for repair surfacing of damaged lining of impeller chamber of hes hydropower units.
The Paton Welding J., 06, 90-92.