The Paton Welding Journal, 2002, #9, 43-45 pages
Distribution of induction of control longitudinal magnetic field in welding T-joints
S.M. Sidorenko1, A.D. Razmyshlyaev1, V.R. Maevsky2
1Priazovsky State Technical University, Mariupol, Ukraine
2Company «Azovmash», Mariupol, Ukraine
Abstract
In welding of T-joints from ferromagnetic steels a longitudinal component of control longitudinal magnetic field in the arc zone is 2-3 times lower than that in surfacing on flat surface. Optimum sizes of solenoid, generating a longitudinal magnetic field, are defined at which the required level of induction in the welding arc zone in ferromagnetic steel T-joint welding is provided.
Keywords: submerged-arc welding, ferromagnetic steels, T-joints, magnetic field, induction, solenoid, calculations, investigations
References
1. Razmyshlyaev, A.D., Maevsky, V.R., Sidorenko, S.M. (2001) Calculation of magnetic field induction of a solenoid with a ferromagnetic core for arc surfacing. The Paton Welding J., 8, 18-21.
2. Razmyshlyaev A.D. (1996) Influence of magnetic field on sizes of penetration zone in submerged-arc surfacing. Avtomatich. Svarka, 8, 25-26, 30.
3. Akulov, A.I., Belchuk, G.A., Demyantsevich, V.P. (1977) Technology and equipment of fusion welding. Moscow: Mashinostroenie.
Suggested Citation
S.M. Sidorenko,
A.D. Razmyshlyaev,
V.R. Maevsky (2002) Distribution of induction of control longitudinal magnetic field in welding T-joints.
The Paton Welding J., 09, 43-45.