Technical Diagnostics and Non-Destructive Testing #4, 2023, pp. 42-49

Tank technical condition monitoring at the ukrainian antarctic station «Academik Vernadsky»

Yu.M. Posypaiko1, A.M. Andreev2

1E.O. Paton Electric Welding Institute of the NAS of Ukraine 11 Kazymyr Malevych Str., 03150, Kyiv, Ukraine. E-mail: office@paton.kiev.ua
2National Antarctic Scientific Center of the Ministry of Education and Science of Ukraine. 16 T. Shevchenko Blvd., 01016, Kyiv. E-mail: uac@uac.gov.ua

Diagnostics of the technical condition of metal structures of tanks and pipelines at «Akademik Vernadsky» UAS was carried out.At the preparatory stage, an analysis of design and operational documentation for tanks was performed, technical inspection methods were selected, equipment and auxiliary equipment were selected for performing diagnostic work using non-destructive testing methods. An instrumental inspection of the condition of metal structures of tanks and pipelines was carried out using nondestructive testing methods in order to identify defects and damage in structural elements and welded joints, an inspection of the condition of the foundation and base of the tank. Anti-corrosion work was carried out on the bottom of the tank and pipelines that had unacceptable corrosion damage were replaced. All elements of the tanks are in working technical condition and comply with current norms and standards for design, manufacture and operation. The static strength of the wall of the external and internal tanks corresponds to the project and current regulations. Due to anti-corrosion work on the bottom of the internal tank of RVS-200, its operation can be continued until 2029, provided that the rules for the technical operation of the tanks and the organization of annual monitoring of the technical condition of the tanks and technological equipment are followed. 20 Ref., 5 Fig.
Keywords: tanks, technical condition monitoring, non-destructive testing methods, defects, damage

Received 18.09.2023

References

1. Law of Ukraine dated January 18, 2001 No. 2245-ІІІ «On objects of increased danger? [in Ukrainian].
2. Resolution of the Verkhovna Rada of Ukraine «On accession to the Antarctic Treaty» No. 2609-ХІ of.17.09.1992 [in Ukrainian].
3. Law of Ukraine dated February 22, 2001 No. 2284-ІІІ «On Ukraine’s Accession to the Protocol on Environmental Protection to the Antarctic Treaty» [in Ukrainian].
4. COMNAR Accident Incident and Near Miss Reporting (AINMR) System. https://www.comnap.aq/membersonly/ AINMR/SitePages/Home.aspx.
5. АРІ 653-2014 Tank Inspection, Repair, Alteration and Reconstruction.
6. EN 14015-2004 Specification for the design and manufacture of site built, vertical, cylindrical, flat-bottomed, above ground, welded, steel tanks for the storage of liquids at ambient temperature and above.
7. (1988) Rules for the technical operation of tanks and instructions for their repair. Moscow, Nedra [in Russian].
8. (1997) Additions and changes to the «Rules for technical operation of tanks and instructions for their repair». Kyiv, JSC «Ukrnaftoprodukt» [in Russian].
9. (1998) Rules for technical operation and labor protection at oil storage depots. Kyiv, Ukrnaftoprodukt [in Russian].
10. (1994) VBN B.2.2-58.2-94 Vertical steel tanks for storing oil and oil products with saturated vapor pressure not higher than 93.3 kPa. Kyiv, Derzhkomnaftogaz [in Ukrainian].
11. (2012) DSTU B V.2.6-183:2011 Vertical cylindrical steel tanks for oil and oil products. General technical conditions (GOST 31385-2008, NEQ). Kyiv, Ministry of Regions of Ukraine [in Ukrainian].
12. (2009) DBN V.1.2-14–2009 General principles of ensuring the reliability and structural safety of buildings, structures, construction structures and foundations [in Ukrainian].
13. (2009) DSTU NBA.3.1-10:2008 Guidelines for conducting technical diagnostics of vertical steel tanks. Kyiv, Minregionbud Ukrainy [in Ukrainian].
14. Posypaiko, Yu.M. (2016) Flaw detection in Antarctic. Technical diagnostics of RVS-200 tank in Ukrainian Antarctic station «Academik Vernadskii». Tekh. Diagnost. i Nerazrush. Kontrol, 4 , 46-51. [in Ukrainian] https://doi.org/10.15407/tdnk2016.04.08
15. Posypaiko, Yu.M. (2016) Technical diagnostics of RVS-200 tank in UAS «Academik Vernadskii». In: Proc. of 8th Nat. Sci.-Tekh. Conf. on Non-destructive Testing and Technical Diagnostics. Kyiv, 104-109 [in Ukrainian].
16. Zhuk, G.V., Moroz, I.V., Barvinko, A.Yu. et al. (2017) Peculiarities of construction and service of tank RVS-200 for storage of diesel fuel in Antarctica at the station «Akademik Vernadsky». The Paton Welding J., 2, 33-37. https://doi.org/10.15407/tpwj2017.02.07
17. Posypajko, Yu.M. (2017) Tanks in Antarctica: Construction and diagnostics. Svarshchik, 4, 44–49 [in Ukrainian].
18. (2016) Technical report (expert opinion) on the technical condition of the RVS-200 tank installed at the Ukrainian Antarctic Station «Akademik Vernadsky». Kyiv, PWI [in Ukrainian].
19. (2019) Conclusion on the technical condition of the RGS-150 tank installed on the UAS «Akademik Vernadsky» on the island of Galindez in the archipelago of the Argentine Islands. Kyiv, PWI [in Ukrainian].
20. (2019) Technical report on the condition and repair of the bottom of the RVS-200 tank installed on the UAS «Akademik Vernadsky» on the island of Galindez in the archipelago of the Argentine islands.Kyiv, PWI [in Ukrainian].

Advertising in this issue: