Influence of working frequency on dimensions of transformers for ac resistance welding

Yu.N. Lankin


E.O. Paton Electric Welding Institute, NASU, Kiev, Ukraine
 
 
Abstract
The paper deals with a resistance welding machine powered from a high-frequency mains. Effect of working frequency increase compared to industrial frequency on the volume of machine transformer core was studied. It is shown that frequency increase does not lower the overall dimensions and weight of the transformer and it is not rational to supply power to AC resistance welding machines of medium and high power from a higher frequency inverter.
 
 
Keywords: resistance welding, inverter, welding machine, transformer, secondary circuit, magnet core volume
 
 
Received:                ??.??.??
Published:               28.04.10
 
 
References
1. Gorsky, A.N., Rusin, Yu.S., Ivanov, N.P. et al. (1988) Calculation of electromagnetic elements of secondary power supplies. Moscow: Radio i Svyaz.
2. Ryskova, Z.A., Fedotov, P.D., Zhimereva, V.I. (1990) Transformers for resistance welding. Leningrad: Energoatomizdat.
3. Budilov, B.A., Glazov, V.V., Komarchev, A.I. et al. Machine for resistance welding. Pat. 2047444 RF. Int. Cl. B23K111/24. Appl. 07.02.1994. Publ. 10.11.1995.
4. Glebov, L.V., Peskarev, N.A., Fajgenbaum, D.S. (1981) Calculation and design of resistance welding machines. Leningrad: Energoatomizdat.

Suggested Citation

Yu.N. Lankin (2010) Influence of working frequency on dimensions of transformers for ac resistance welding. The Paton Welding J., 04, 49-50.