Eng
Ukr
Rus
Print

2020 №03 (08) DOI of Article
10.37434/tdnk2020.03.09
2020 №03 (01)

Technical Diagnostics and Non-Destructive Testing 2020 #03
Technical Diagnostics and Non-Destructive Testing #3, 2020, pp. 58-60

Dynamics and diagnostics of clearances in multi-stand rolling

A.V. Baglay1, V.V. Verenev2


1SE «DIAMECH-UKRAINE». 19 Kirgizska str., 61105, Kharkiv, Ukraine. E-mail: baglay@diamech.com.ua
2Z.I. Nekrasov Iron and Steel Institute of NAS of Ukraine, 1 Academician Starodubov Square, 49050, Dnipro, Ukraine. E-mail: office.isi@nas.gov.ua

The types of transients on the torque in three stands of a small-grade mill at two-thread rolling are presented. Their features during the capture of the first strip and then the second strip are described. A method is proposed for calculating the coefficient of dynamism and the maximum peak load, when the next strips enter the rolls under load. The possibility of determination of the technical condition of the drive line in terms of wear and clearances is shown. 2 Ref., 1 Tabl., 1 Fig.
Keywords: strip capture, caliber, two-thread rolling, torque, oscillations, clearance, drive line, dnamism factor

Received: 10.07.2020

References

1. Verenev, V.V. (2007) Diagnostics and dynamics of rolling mills. Dniepropetrovsk, IMA-press [ in Russian].
2. Verenev, V.V. (2014) Lowering of dynamic loads and diagnostics of broadband mills in transient modes. Nikopol, SPD Feldman O.O. [in Russian].